| American Society of Mechanical Engineers - 1884 - 658 páginas
...paper, and the. directions are, after hauling fires, etc., to " as quickly as possible start afresh fire with weighed wood and coal, noting the time of starting the test at the instant the fire is lighted," and again provides for " noting the end of the test at the time... | |
| American Society of Mechanical Engineers - 1884 - 486 páginas
...rapidly all the fire from the grate, and clean the ash pit, and as quickly as possible start a fresh fire with weighed wood and coal noting the time of starting the test at the instant the fire is lighted. At the end, burn the fires low as at the beginning, and remove... | |
| 1885 - 566 páginas
...working pressure, remove rapidly all the fire from the grate, close the damper, clean the ash pit, and as quickly as possible start a new fire with weighed...while the water is in a quiescent state, just before lighting the fire. At the end of the test, remove the whole fire, clean the grates and ash pit, and... | |
| Robert Henry Thurston - 1890 - 546 páginas
...temperatures of the walls and flues, the following method of starting and stopping a test should be adopted : X. Standard Method. — Steam being raised...the time of starting the test and the height of the water-level while the water is in a quiescent state, just before lighting the fire. At the end of the... | |
| Robert Henry Thurston - 1890 - 704 páginas
...temperatures of the walls and flues, the following method of starting and stopping a test should be adopted : X. Standard Method. — Steam being raised...the time of starting the test and the height of the water-level while the water is in a quiescent state, just before lighting the fire. At the end of the... | |
| Rolla Clinton Carpenter - 1892 - 830 páginas
...temperatures of the walls and flues, the following method of starting and stopping a test should be adopted : X. Standard Method. — Steam being raised...the time of starting the test and the height of the water-level while the water is in a quiescent state, just before lighting the fire. At the end of the... | |
| Park Benjamin - 1892 - 962 páginas
...temperatures of the walls and flues, the following method of starting and stopping a test should be adopted : " X. Standard Method. — Steam being raised...the time of starting the test and the height of the water-level while the water is in a quiescent state, just before lighting the fire. At the end of the... | |
| Park Benjamin - 1892 - 970 páginas
...fire from the grate, close the damper, clean the ash-pit, and as quickly as possible start a new flre with weighed wood and coal, noting the time of starting the test and the height of the water-level while the water is in a quiescent state, just before lighting the flre. At the end of the... | |
| Heine Safety Boiler Company - 1893 - 184 páginas
...temperatures of the walls and flues, the following method of starting and stopping a test should be adopted : Standard Method. — Steam being raised to the working...the time of starting the test and the height of the water-level while the water is in a quiescent state, just before lighting the fire. At the end of the... | |
| 1895 - 220 páginas
...working pressure, remove rapidly all the fire from the grate, close the damper, clean the ash pit, and as quickly as possible start a new fire with weighed wood and coal, noting the tone of starting test and the height of the water level while the water is in a quiescent state just... | |
| |