Página 9 - Bolten, being duly sworn, deposes and says that he is the petitioner or memorialist named iu the foregoing memorial or petition subscribed by him; that he has read the same and knows the contents thereof, and that the same is true of his own knowledge, except as to the matters therein stated to be alleged on information and belief, and that as to those matters he believes it to be true.
Página 485 - Automatic cut-outs must be placed at every point where a change is made in the size of wire, unless the cut-out in the larger wire will protect the smaller (see § 418 of this chapter).
Página 149 - The Constitution of the United States is a law for rulers and people, equally in war and in peace, and covers with the shield of its protection all classes of men, at all times, and under all circumstances.
Página 413 - ... the city of New York and of any of the municipal and public corporations, or parts of municipal and public corporations by this act consolidated with the municipal corporation known as the mayor, aldermen and commonalty of the city of New York...
Página 488 - Higid supporting requires under ordinary conditions, where wiring along flat surfaces, supports at least every four and one-half feet. If the wires are liable , to be disturbed, the distance between supports should be shortened. In buildings of mill construction, mains of No.
Página 79 - If at any time during the session of the Senate a question shall be raised by any Senator as to the presence of a quorum, the presiding officer shall forthwith direct the...
Página 502 - Lighting and Power from Railway Wires. a. Must not be permitted, under any pretense, in the same circuit with trolley wires with a ground return, except in electric railway cars, electric car houses, power houses, passenger and freight stations connected with the operation of electric railways.
Página 492 - All elbows or bends must be so made that the conduit or lining of same will not be injured. The radius of the curve of the inner edge of any elbow not to be less than 3i inches. Must have not more than the equivalent of four quarter bends from outlet to outlet, the bends at the outlets not being counted.
Página 505 - National Electrical Code Standard." 3. Name of the manufacturing company and, if desired, trade name of the wire. 4. Month and year when manufactured.
Página 477 - Metal conduits[,] containing service wires must be [insulated from the metal conduit, metal moulding, or armored cable system within the building and all metal work on or in the building, or they must have the metal of the conduit permanently and effectually grounded to water piping, gas piping or other suitable grounds, provided that when connections are made to gas piping, they must be on the street side of the meter.